Lennox nomenclature model number - 102, 120 & 150 MODELS “LCA” PACKAGED COOLING & ELECTRIC HEAT “LGA” PACKAGED COOLING & GAS HEAT “LHA” PACKAGED HEAT PUMP *Net Cooling Capacity - 101,000 to 138,000 Btuh (29.6 to 40.4 kW)

 
Multi-Stage Operation. Responding to changing conditions, the 16ACX adjusts to maximize energy savings—operating at lower speed most of the time, and ramping up during periods of increased cooling demand. This multi-stage operation also translates to enhanced humidity control. See How It Works.. Forrest county jail hattiesburg new jail mugshots

MODEL NUMBER IDENTIFICATION RESIDENTIAL PRODUCT SPECIFICATIONS Ratings Revision Level (NOTE - 018-024-030-036-042 models only) Regional Standards ... NOTE - Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. APPLICATIONS • 1.5 through 5 tonsModel/Part Number 13ACX-036-230 Minimum Order Quantity 0.0 Base Unit of Measure Unit(S) Product Voltage 208/230v 1ph 60 hz Refrigerant. R-410A . Gross Weight. 135 LB. Family. 13ACX . Cooling Capacity. 3.0 Ton Cooling ... I DO NOT have a Lennox Customer Number. CONTINUE close Stock Availability ...Lennox Elite EL296V, EL296UH090XV48C, 96% AFUE, 88000 BTU, 4 Ton, 2 Stage Heat, Variable Speed Upflow/Horizontal Gas Furnace. Cat # : 62W90. Model/Part # : EL296UH090XV48CLennox (NYSE: LII) is a leader in energy-efficient climate-control solutions. Dedicated to sustainability and creating comfortable and healthier environments for our residential and commercial customers while reducing their carbon footprint, we lead the field in innovation with our cooling, heating, indoor air quality, and refrigeration systems.Trane Model Number Nomenclature. OK, here is the breakdown of the Trane model lookup for models from 10 to 19 SEER, which covers most Trane ACs and heat pumps currently in use. Here is our sample Trane XL16i model number: 4TTX6048J. The model number tells us that this is a 16 SEER AC, and its size is 48,000 BTU or 4 tons.Model No. Catalog No. Unit Model No. KGB 024 KGB 030 KGA KGB 036 KGA KGB 048 KGA KGB 060 KGA KGB 072 KGB 074 KGA 090 ROOF CURBS HyErid 5oof CurEs DoZnÀoZ 8 in. height C1CURB70A-1 11F50 XXXXXXX1 X 14 in. height C1CURB71A-1 11F51 XXXXXXX1 X 18 in. height C1CURB72A-1 11F52 XXXXXXX1 X 24 in. height C1CURB73A-1 11F53 XXXXXXX1 X HyErid 5oof CurEs ...Condensate Drain Heat Cable Kits. − Selflimiting wattage heat cable prevents condensate drain from freezing in unconditioned areas. − Available in 6, 24 or 50 ft. (1.8, 7.3, or 15.2 m) lengths. − See specifications table for order number. Heat Cable Tape: − 66 ft. (20 m) length, 1/2 in. (13 mm) wide fiberglass.MODEL NUMBER IDENTIFICATION TGA090 H 2 B S 1 Y Major Design Sequence A = 1st Generation B = 2nd Generation C = 3rd Generation E = 4th Generation Brand/Family T = T−Class Product Line Unit Type G = Packaged Gas Heat w/ Electric Cooling Nominal Cooling Capacity − Tons 090 = 7.5 Tons 102 = 8.5 Tons 120 = 10 Tons 150 = 12.5 Tons Cooling EfficiencyCopeland Scroll refrigeration compressors (such as ZBxxKA-PFV) are designated by a "Z" in the first position of the model number. The second position determines the application range (B = high/medium temperature, S = medium temperature, F = low temperature).• All models are ASHRAE 90.1-2010 energy efficiency compliant and meet or exceed requirements of Section 6.8 • All models meet DOE 2018 energy efficiency standards • All models meet California Code of Regulations, Title 24 and ASHRAE 90.1-2010 Section 6.4.3.10 requirements for staged airflow • ENERGY STAR® certified%PDF-1.5 %âãÏÓ 280 0 obj > endobj 300 0 obj >/Filter/FlateDecode/ID[1BBBE75283E426F2E7A4E65AA48DEFC4>]/Index[280 39]/Info 279 0 R/Length 100/Prev 892984/Root 281 ...13ACX Air Conditioner. Economical, environmentally responsible home cooling. Even in the hottest summer months, the 13ACX-030-230 works efficiently to enhance your customers' comfort. Compared to an older system, this air conditioner can help them save significantly on their monthly cooling bills. ALL REGIONS. Energy Efficiency. Quiet Operation.Lennox, Air Conditioner, T CLASS, 4 Ton, 14 SEER, 1 Stage, 208-230 VAC 3 Ph 60 Hz, TSA048S4N44Y. Cat # : 14V84. Model/Part # : TSA048S4N44YWhen you own a Craftsman tool or piece of equipment, you know you can depend on quality and exceptional workmanship. Built to stand the test of time, the Craftsman brand is synonym...The year of manufacture for Lennox equipment is encoded in the serial number and is indicated by the third and fourth position numbers. (For example, if YY was 01 that would indicate that the unit was manufactured in 2001). 77YYX77777 (The 3rd and 4th number indicates the year of manufacture — after 1992) Luxaire. See York. Maytag. See Nortek ... Lennox Serial Number Nomenclature - Free download as PDF File (.pdf), Text File (.txt) or read online for free. Lennox serial number decoding Looking for more information about your Lennox product? Find your owner’s literature, like product manuals, by searching your product’s model number.The Lennox CB29M and CB30M Elite. series blower coil. units are designed for installation with a matched remote. outdoor unit and optional field−installed electric heat. The. blower coil units are for indoor installation only. The CB29M and CB30M units, designed for multi−position-. al installations, are completely assembled at the factory.40+ years of Trane serial numbers: This page explains or decodes seven Trane serial number styles, making the date lookup very easy for any year going back to the 1970s.The numbers were/are used on ACs, heat pumps, furnaces, air handlers and other equipment types. Not Model #s: This post is about Trane serial numbers, not Trane model numbers that have nomenclature related to the series, size ...FEATURES ALL MODELS Item LCA/LGA/LHA180 LCA/LGA210 LCA/LGA/LHA240 Air Flow Choice — Bottom (down-flow) or horizontal (side) supply and return air Standard Standard Standard Bottom Power Electrical/Gas Entry Standard Standard Standard Cabinet — Heavy gauge galvanized steel, fully insulated, powdered enamel paint fin- ish, large removeable access panels, electrical inlets in cabinet base and ...The model and serial numbers for your cooling system can be found on the nameplate or sticker, located near the service panel. The nomenclature sticker should have a white background with black letters.Model Number. Blower Type. Net Cooling Capacity (Btuh) Cooling Stages. High. LCH/LGH 036H4E. Direct. 35,200. Standard. LCH/LGH 036S4T. Belt. 34,800. 2. High. LCH/LGH …Lennox DMS1 Nomenclature. MODEL NUMBER. Model Number. *Gas heating capacity (Btuh) Oil Heat exchanger model no. Burner model no. *Oil heating …MODEL NUMBER IDENTIFICATION THA090 S 2 B E 1 Y Major Design Sequence A = 1st Generation B = 2nd Generation C = 3rd Generation E = 4th Generation Brand/Family T = T−Class Product Line Unit Type H = Packaged Heat Pump Nominal Cooling Capacity − Tons 090 = 7.5 Tons 102 = 8.5 Tons 120 = 10 Tons 150 = 12.5 Tons Cooling Efficiency S = Standard ...Number and size of filters (in.) Optional Roof Mounting Frame (used with RDE16–41 only) Optional ••Economizer Dampers Model No. 3 position Modulating Number and size of filters (in.) Optional Ceiling Supply and Return Air Diffusers Step Down Flush Transition 7.8 23,200 2650 9.8 8.7 2 lbs. 12 oz. 9 x 7 1/3 600 – 1000 3.20 3/8 – 2 15 6. ...Lennox model numbers 14= 1 ton 21= 1-1/2 ton 26= 2 ton 31= 2-1/2 ton 41= 3 ton 46= 3-1/2 ton 51= 4 ton 65= 5 ton So, your unit is a two ton model. The HS stands for high side, HP for heat pump. The next two numbers are the series of unit, they generally work up as they introduce new models. Then a dash and the next two digits which are …2010 Lennox Industries Inc. Dallas, Texas, USA WARNING Improper installation, adjustment, alteration, service or maintenance can cause personal injury, loss of life, or ... Model Number Corner Weights Center Of Gravity AA BB CC DD EE FF lbs. lbs. lbs. lbs. in. in. 15GCSXAV−24 74 94 125 97 15.5 28.5FEATURES Item GCS24-953 GCS24-1353 GCS24-1603 GCS24-3003 Air Flow Choice — Bottom (down-flow) or horizontal (side) supply and return air Std. Std. Std. Std. Approvals — A.G.A./C.G.A. certified as combination heating/ cooling unit for outdoor installation, bonded for grounding to meet safety standards forGCS16−024−036−048−060. ENGINEERING DATA. Net Cooling − 5.9 to 15.4 kW (20 000 to 52 500 Btuh) Net Heating − 12.9 to 30.8 kW (44 000 to 105 000 Btuh) Bulletin No. 490105. June 2002. Rooftop Installation With Combination Supply and Return Air System. Rooftop Installation With Horizontal Economizer. MODEL NUMBER IDENTIFICATION.Brand® History¹. 1895 - Lennox founded in Marshalltwon, Iowa by Dave Lennox - builds and markets the industries first riveted steel furnace. 1904 - Dave Lennox sells business to D.W. Norris, who incorporated the business as Lennox Furnace Company and proceeds to sell 600 furnaces in the company's first year. 1923 - Lennox expands to Syracuse, New YorkThe Lennox ELITE® Series CBA27UHE family of air handlers makes it easy to save money on energy bills, year after year. That’s because it is the first family of air handlers to use the Quantum™ Coil; a proprietary, enhanced aluminum tube and fin coil engineered for long-lasting corrosion resistance. The CBA27UHE-036-230 provides reliable ...Model/Part # : ML180UH090P36B. Product Unavailable Please call 1-877-570-0123 for more information. Print. Quantity: Add to Cart. Save to List. Save Item to List ×. Select list: ... I have a Lennox Customer Number. I DO NOT have a Lennox Customer Number. CONTINUE close Stock Availability ... MODEL NUMBER IDENTIFICATION TGA M090 S 2 B S 1 Major Design Sequence A = 1st Generation B = 2nd Generation C = 3rd Generation E = 4th Generation Brand/Family T = T−Class Product Line Unit Type G = Packaged Gas Heat w/ Electric Cooling Nominal Cooling Capacity − kW 090 = 26.4 kW 102 = 29.9 kW 120 = 35.2 kW 150 = 44.0 kW Cooling Efficiency Lennox (NYSE: LII) is a leader in energy-efficient climate-control solutions. Dedicated to sustainability and creating comfortable and healthier environments for our residential and commercial customers while reducing their carbon footprint, we lead the field in innovation with our cooling, heating, indoor air quality, and refrigeration systems.Lennox, 20-25 year old residential air conditioner. Nomenclature reads a model # HS8-461, can anyone tell me the correct tonnage of this unit. It appears to be a 2.5 or 3 ton judging by the suction and discharge line sizes of 3/4" suction and 1/4" liquid. It definately is not a 4-ton unit if anyone is rounding the 46 in the nomencalture to a 48 signifying to most a 4-ton unit.The new Model L™ is the most powerful, most advanced rooftop unit in the industry. Advanced Industry LENNOX WEBINARS. Register to receive information about our webinars! ... Lennox Global. Address: 11420 N Kendall Drive, Suite 103 Miami, FL 33176. Phone: +1 305-718-2901. CONNECT WITH US (opens in new window) (opens in new window)Offering industry-leading efficiencies of up to 26.00 SEER, Lennox air conditioners can help you save hundreds of dollars every year in utility costs. And since some of the units are ENERGY STAR ® certified, they may even qualify you for federal energy tax credits and local utility rebates. In addition, a number of Lennox air conditioners work ...A number model in math is a sentence that illustrates how the parts of a number story are related. The equation may include addition, subtraction, division and multiplication and m...3 days ago · If you're an HVAC contractor or technician interested in a free test procedure describing simple testing you can do on a sales visit, contact Doc at [email protected] or call him at 800-633-7058. Go to NCI’s website at nationalcomfortinstitute.com for free information, articles, and downloads. Download. MODEL NUMBER IDENTIFICATION ML 1 93 UH 070 X P 36 B Unit Type ML = Merit ® Series Stages 1 = One-Stage Nominal Gas Heat Input Blower 045 = 44,000 Btuh 070 = 66,000 Btuh 090 = 88,000 Btuh 110 = 110,000 Btuh 135 = 132,000 Btuh P = PSC Multi-Speed Blower Motor Nominal Add-On Cooling Capacity 24 = 2 tons 36 = 3 tons 48 = 4 tons 60 = 5 tons ...The ML17XP1 offers energy efficiencies of up to 18.60 SEER and 10.60 HSPF, equivalent to 17.00 SEER2 and 8.50 HSPF2, delivering comfort and energy savings at a more affordable price.model number lch/lgh 120h4b lch/lgh 120h4m lch/lgh 150h4b lch/lgh 150h4m lch/lgh 156h4b lch/lgh 156h4m/v lch/lgh 180h4b lch/lgh 180h4m/v lch/lgh 210h4b lch/lgh 210h4m lch/lgh 240h4b lch/lgh 240h4m/v lch/lgh 300s4b lch/lgh 300s4m blower type cav msav cav msav cav msav/vav cav msav/vav cav msav cav msav/vav cav msav net cooling capacity (btuh ...How to Read a Lennox Serial Number. This Lennox serial number lookup works for the Lennox age of unit lookup on air conditioners, heat pumps, gas furnaces, air handlers, boilers and mini split ductless heat pumps.Number and size − in. (mm) (4) 18 x 24 x 2 (457 x 610 x 51) Electrical characteristics 208/230V, 460V or 575V − 60 hertz − 3 phase NOTE − Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction.Cleanable Filter. Applications — G20E series gas fired furnaces include ten mod-els with input capacities of 50,000, 75,000, 100,000, 125,000 and 150,000 Btuh (14.7, 22.0, 29.3, 36.6 and 44.0 kW) and energy effi-ciencies (AFUE) of 78.0%. G20E models are available with either natural gas or LPG/Propane. G20X models are available with natural ...Lennox, Air Conditioner, T CLASS, 4 Ton, 14 SEER, 1 Stage, 208-230 VAC 3 Ph 60 Hz, TSA048S4N44Y. Cat # : 14V84. Model/Part # : TSA048S4N44YOn other Lennox products the plate is mounted on the outside of unit. The sequence of letters and digits in the Lennox model number reflects specific information about the unit. The figures below analyze two typical model numbers. HS26-060-1P HS26 is the Series, 060 is the Capacity, 1P (1) is the Dash Number and (P) is the Power Characteristics.MODEL NUMBER IDENTIFICATION LGC Y240 S 2 B S 1 Major Design Sequence A = 1st Generation B = 2nd Generation C = 3rd Generation E = 4th Generation Brand/Family ... Lennox was the first HVAC manufacturer to win this award and has been a four−time recipient since 2003. ISO 9001 Registered Manufacturing Quality System.The model and serial numbers of each of the Lennox company’s furnaces is visible inside the top-front service panel of the furnace. The model and serial numbers are located by look...Lennox, 20-25 year old residential air conditioner. Nomenclature reads a model # HS8-461, can anyone tell me the correct tonnage of this unit. It appears to be a 2.5 or 3 ton judging by the suction and discharge line sizes of 3/4" suction and 1/4" liquid. It definately is not a 4-ton unit if anyone is rounding the 46 in the nomencalture to a 48 signifying to most a 4-ton unit.4.1. (49) * Based on sound pressure levels during operation of Lennox's CBA38MV-036 with factory-installed filter compared against 3-ton units of the leading competitors representing the majority of the total air handlers of like class sales volume in North America at equivalent external static pressure when set up per Section 4.5.3 of AHRI ...FEATURES − LCA MODELS Item LCA156H LCA180 LCA210 LCA240 LCA300S Approvals E.T.L. and C.G.A. listed, efficiency rating verified by C,.S.A., componentsThe serial number, not the model number, is what will give us the information we need to help determine the age. find the data tag if there is one, then see SEARS / KENMORE HVAC AGE MANUALS & PARTS. On 2022-08-30 by Bart . I have an old Sears/Homart boiler (model #: 229-111). Can someone PLEASE tell me the year that this was manufactured? Thanks.Aug 21, 2023 · How to determine the date of production/manufacture or age of Lennox ® brand HVAC Systems. The industry average service design life for most forced air furnaces is 15-20 years, and the industry average service design life for most air conditioning condensing units is 10-15 years. The average service design life of boilers can vary from as ... The 135,000 pre-orders for the $35,000 Tesla Model 3 translate into over $4.7 billion in sales. By clicking "TRY IT", I agree to receive newsletters and promotions from Money and i...Single-Stage, 96% Fuel-Efficient Gas Furnace with Power Saver™ Constant-Torque Motor Design. The Power Saver™ constant torque motor in the ML196E uses less energy in both heating and cooling modes, helping you save on utility bills. Flexible airflow based on a home's ductwork makes this furnace 33% more efficient than older furnaces ...Multi-Stage Operation. Responding to changing conditions, the 16ACX adjusts to maximize energy savings—operating at lower speed most of the time, and ramping up during periods of increased cooling demand. This multi-stage operation also translates to enhanced humidity control. See How It Works.©2017 Lennox Industries Inc. Dallas, Texas, USA 506476-01 04/2017 Supersedes 03/2017 ML193DF SERIES GAS FURNACE WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Installation and service must be performed by a licensed professional HVAC installer orLennox (NYSE: LII) is a leader in energy-efficient climate-control solutions. Dedicated to sustainability and creating comfortable and healthier environments for our residential and commercial customers while reducing their carbon footprint, we lead the field in innovation with our cooling, heating, indoor air quality, and refrigeration systems.Jul 23, 2016 · This is a link to a pdf of the Lennox HVAC equipment model number nomenclatures. http://www3.lennox.com/pdfs/Lennox_Model_and_Serial_Nomenclature.pdf Do you know how to make a 3-D model for oxygen? Find out how to make a 3-D model for oxygen in this article from HowStuffWorks. Advertisement One of the most effective and fun ways...Model/Part Number LH49/61E9C Minimum Order Quantity 0.0 Base Unit of Measure Unit(S) Family. LH . Series. L . Configuration. Horizontal . Nominal Cooling Capacity. 4 to 5 Ton . Metering Device. TXV (R410A) ... I DO NOT have a Lennox Customer Number. CONTINUE close Stock Availability ...Air resistance tests from Lennox Laboratory air test chamber. 1.5 to 5 Tons FEATURES MODEL NUMBER IDENTIFICATION PRODUCT SPECIFICATIONS C 33 - 18 A - 2 F Series Unit Type C = Indoor Coil - Upflow 1 Cabinet Width A = 14-1/2 in. B = 17-1/2 in. C = 21 in. D = 24-1/2 in. Cabinet F - Cased Uncased coils have no designation Metering …Lennox GCS16-953-200-3 - Lennox Packaged Unit/RTU GCS16-953-200-3- Lennox Packaged Unit/RTU GCS16-953-200-3. Free shipping on orders over $99 ...Lennox (NYSE: LII) is a leader in energy-efficient climate-control solutions. Dedicated to sustainability and creating comfortable and healthier environments for our residential and commercial customers while reducing their carbon footprint, we lead the field in innovation with our cooling, heating, indoor air quality, and refrigeration systems.3.1 Model Numbering Systems Introduction All Lennox product is set up with a systematic coding system for both model numbers and serial numbers. Unit model number (including any dash ... tonnage to the Btuh capacities found in model numbers. Old Nomenclature BTU = TONS BTU = TONS -14 = 1 ton -95 = 7½ tons -21 = 1½ tons -135 = 10 tonsMODEL NUMBER IDENTIFICATION CH 35 - 18 A - 2 F Series Unit Type CH = Indoor Coil, Horizontal 2 Cabinet Height A = 14-1/2 in. B = 17-1/2 in. C = 21 in. D = 24-1/2 in. Cabinet ... NOTE - Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. APPROVALS AND WARRANTY.Model No. 2SCU13LC136T 2SCU13LC148T 2SCU13LC160T Nominal Tonnage 3 4 5 Connections (sweat) Liquid line o.d. - in. 3/8 3/8 3/8 Suction line o.d. - in. 7/8 7/8 7/8 1 Refrigerant charge field supplied (R-22) 5 lbs. 12 oz. 7 lbs. 8 oz. 10 lbs. 0 oz. Outdoor Coil Tube diameter - in. 5/16 5/16 5/16 Number of rows 1 1 2 Fins per inch 26 22 22 Outdoor FanCreated Date: 5/2/2002 3:07:14 PM Lennox Serial Number Nomenclature - Free download as PDF File (.pdf), Text File (.txt) or read online for free. Lennox serial number decoding Lennox model number nomenclature - InterNACHI®️ Forum Jul 23, 2016 · Lennox model number nomenclature Specific Inspection Topics Inspecting HVAC Systems sfetty (Dave Fetty, CMI) July 23, 2016, 8:15pm #1 This is a link to a pdf of the Lennox HVAC equipment model number nomenclaturesGuide Specifications. Covering our extensive line of rooftop units, split systems and heating units, these detailed guide specifications provide helpful product information you can depend on.MODEL NUMBER IDENTIFICATION TGA090 H 2 B S 1 Y Major Design Sequence A = 1st Generation B = 2nd Generation C = 3rd Generation E = 4th Generation Brand/Family T = T−Class Product Line Unit Type G = Packaged Gas Heat w/ Electric Cooling Nominal Cooling Capacity − Tons 090 = 7.5 Tons 102 = 8.5 Tons 120 = 10 Tons 150 = 12.5 Tons …MODEL NUMBER NOMENCLATURE. HVAC units are identified by their multiple-character model number that identifies a particular type of unit. Below you will find a partial explanation of the alphanumeric identification code (aka Model Number Nomenclature). Our samples have been simplified to concentrate more on the location of each individual units ...MODEL NUMBER IDENTIFICATION. L . G H 060 H 4 E S 1 Y. Brand/Family. L = E-Series. Unit Type . G = Packaged Gas Heat w/ Electric Cooling . Major Design Sequence. H = 1st Generation. Nominal Cooling Capacity - Tons . 036 = 3 Tons 048 = 4 Tons 060 = 5 Tons 072 = 6 Tons Cooling Efficiency. S = Standard Efficiency H = High Efficiency. Refrigerant ... − Refer to Lennox Equipment Limited Warranty certificate for specific details. Refrigeration System − All models include: check/expansion valve, reversing valve, filter drier, suction and liquid line service gauge ports, high pressure switch (manual reset) and full refrigerant charge. Model/Part # : ZGA060S4B. Product Unavailable Please call 1-877-570-0123 for more information. Print. Quantity: Add to Cart ... I have a Lennox Customer Number.Back-of-the-napkin business model is slang for a draft business model. Entrepreneurs sometimes jot down ideas on any available surface - including napkins. Slang for a draft busine...CBA27UHE Upflow/Horizontal Quantum Coil Air Handler, Power Saver Constant Torque. 1.5- to 5-ton capacities; Voltage options - available in 230/1/60, 460/1/60, *575/1/60 ; Quantum Coil enhanced aluminum coil; Lennox Power Saver technology - constant-torque blower motor boosts system efficiency, helping contractors qualify for energy rebates; Suitable for use with R-410A refrigerantsOn other Lennox products the plate is mounted on the outside of unit. The sequence of letters and digits in the Lennox model number reflects specific information about the unit. The figures below analyze two typical model numbers. HS26-060-1P HS26 is the Series, 060 is the Capacity, 1P (1) is the Dash Number and (P) is the Power Characteristics.

MODEL NUMBER IDENTIFICATION 1 Indoor coils with the same letter designation will physically match the furnace. AFUE 80 = 80% Low NO x X = Units meet California Nitrogen Oxides Standard (40 ng/J) Cabinet Width A = 14-1/2 in. B = 17-1/2 in. C = 21 in. D = 24-1/2 in. PRODUCT SPECIFICATIONS ML180UH UPFLOW/HORIZONTAL GAS FURNACES . Circle k airport blvd

lennox nomenclature model number

Model/Part Number LGH120H4BH Minimum Order Quantity 0.0 Base Unit of Measure Unit(S) EAN / UPC 66255146867 Product Voltage 460v 3ph 60 hz Size/Dimensions 48x60.5x101.5 IN Horsepower. 3 ... I DO NOT have a Lennox Customer Number. CONTINUE close Stock Availability ...Specifier Note: Add the [and gas lines] only if using an Energence (LG) gas/electric model. h. Electrical lines and gas lines][can be brought through the base of the unit or through horizontal knockouts . i. Insulation: 1. All panels adjacent to conditioned air are fully insulated with non‐hygroscopic fiberglass insulation . 2.You can also view G16Q4-125-1 parts diagrams and manuals, watch related videos or review common problems that may help answer your questions to get started on fixing your Furnace model. For additional assistance, please contact our customer service number at 1-800-269-2609, 24 hours a day, seven days a week or send us a message using the live ...On other Lennox products the plate is mounted on the outside of unit. The sequence of letters and digits in the Lennox model number reflects specific information about the unit. The figures below analyze two typical model numbers. HS26-060-1P HS26 is the Series, 060 is the Capacity, 1P (1) is the Dash Number and (P) is the Power Characteristics.MODEL NUMBER NOMENCLATURE. HVAC units are identified by their multiple-character model number that identifies a particular type of unit. Below you will find a partial explanation of the alphanumeric identification code (aka Model Number Nomenclature). Our samples have been simplified to concentrate more on the location of each individual units ...The CHX35 family of coils are designed with aluminum tube construction which provides great heat transfer and additional resistance to environmental contaminants. Durable components, such as corrosion-resistant casing and drain pans, help guard against unexpected service calls. CHX35-42B-6F-1 coil is built to high standards and is backed by ...Lennox CB17 and CBH17 model blower−coil units, de-signed for indoor applications only, are available in two models; CB17 series with up−flow supply air discharge or ... Model Number CB17-95V CBH17-95V CB17-135V CBH17-135V CB17-185V CBH17-185V CB17-275V CBH17-275V Nominal Cooling Capacity Tons (kW) 7-1/2 (26) 10 (35) 15 (53) 20 (70)We have 2 Lennox G23Q2/3-75 manuals available for free PDF download: Unit Information, Installation Instructions Manual . Lennox G23Q2/3-75 Unit Information (53 pages) G23/G23X SERIES. Brand: Lennox ...4 Lennox Model Number Nomenclature 2021-10-12 demonstrate key concepts related to radiographic interpretation, relevant anatomy, and diagnostic, surgical, and therapeutic techniques. Now in full color, this edition adds coverage of more surgical procedures and expands coverage of zoonotic disease. From editors• All models are ASHRAE 90.1-2010 energy efficiency compliant and meet or exceed requirements of Section 6.8 • All models meet DOE 2018 energy efficiency standards • All models meet California Code of Regulations, Title 24 and ASHRAE 90.1-2010 Section 6.4.3.10 requirements for staged airflow • ENERGY STAR® certifiedHS29−120 units have two outdoor fans. HS29−180 and HS29−240 units have four outdoor fans. Direct drive fan(s) moves large volumes of air uniformly through entire condenser coil(s) for high refrigerant cooling capacity. Upward discharge of air reduces operating sound levels and prevents damage to lawns, shrubs, and walkways.NOTE − Due to Lennox' ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. ... Model Number HS29−072 HS29−090 HS29−120 HS29−180 HS29−240Lennox stamps the model numbers and essential product details on its nameplate. Except for gas and oil furnaces, where the data plate is located inside the cabinet, near the vestibule panel. All Lennox products display the model number outside the unit. Keep on reading the article to know more about Lennox model numbers and other related topics.MODEL NUMBER IDENTIFICATION TGA060 S 2 B S 1 Y Major Design Sequence A = 1st Generation B = 2nd Generation Brand/Family T = T−Class Product Line Unit Type G = Packaged Gas Heat w/ Electric Cooling Nominal Cooling Capacity − Tons 024 = 2 Tons 030 = 2.5 Tons 036 = 3 Tons 048 = 4 Tons 060 = 5 Tons 072 = 6 Tons Cooling Efficiency S = Standard ...Hi! I'm looking at three very old Mammoth rooftop units. I need to know the tonnage of these units. Is anybody here familiar with the Mammoth nomenclature? Here are the model numbers: DHEBFRC-162-3256-L275-M24 DHEBFRC-171-G256-L275-M25 DHEBFRC-212-G256-L275-M26 Any information would be greatly appreciated!Lennox Model Number Nomenclature 3 3 microscale, analyzes bioassay-directed fractionation and other means of isolating biologically active compounds from plants and other sources, covers vital enzymes isolated from marine organisms such as algae, and more. HVAC Troubleshooting Guide Cambridge University Press Patient-reported outcomes (PROs) areService Literature. G40UH (X) series units are mid−efficiency gas furnaces. used for upflow or horizontal applications only, manufac-. tured with Lennox Duralok Plus heat exchangers formed of. aluminized steel. G40UH (X) units are available in heating. capacities of 44,000 to 154,000 Btuh and cooling applica-. tions up to 5 tons..